fix: RDP health check uses correct 19-byte X.224 packet
Yesterday's malformed packet (TPKT len=0x1b mismatch) made health check always fail -> every enable triggered needless TermService restarts and false 'STILL FAILING' reports (root cause of 2026-07-23 morning incident)
This commit is contained in:
+3
-2
@@ -246,8 +246,9 @@ def _rdp_health_check():
|
||||
import socket as _sk
|
||||
try:
|
||||
_s = _sk.create_connection(('127.0.0.1', 3389), timeout=5)
|
||||
# X.224 Connection Request + RDP Negotiation Request (HYBRID)
|
||||
_s.sendall(bytes.fromhex('0300001b13e0000000000001000800020000000000000000000000000'))
|
||||
# X.224 Connection Request + RDP Negotiation Request (SSL|HYBRID|RDSTLS)
|
||||
# TPKT len=0x13(19) 必须等于实际包长,否则服务器正确 RST(2026-07-22 误诊教训)
|
||||
_s.sendall(bytes.fromhex('030000130ee00000000000010008000b000000'))
|
||||
_s.settimeout(5)
|
||||
_resp = _s.recv(1024)
|
||||
_s.close()
|
||||
|
||||
Reference in New Issue
Block a user